ThinLine II 5395
ThinLine II 5395
Overview:
Providing performance and reliability, HID’s attractive, unobtrusive ThinLine II® proximity card reader is housed in a two-piece, weatherproof secure potted enclosure.
- The size of most standard U.S. switch plates.
- Available with Wiegand or Clock-and-Data interface.
- Potted reader suitable for indoor or outdoor use.
- Base part numbers: 5395 (Wiegand), 5398 (Clock-and-Data).
- 18″ (45 cm) wire pigtail standard; consult factory for 9′ (2.7 m) pigtail available by special order.
Key Features
- Easily installed and maintained with the use of replaceable covers.
- Available with a Wiegand or Clock-and-Data interface.
- Provides high reliability, consistent read range and low power consumption.
- Features include multicolor LED and internal control or host control of the LED and beeper.
- Mounts directly on metal with minimal impact on the read range performance.
- Aesthetic design available in two cover designs and four colors to match any décor.
- Includes multilingual installation manual.
Typical maximum* read range
ProxCard® II Card – up to 5.5″ (14 cm)
ISOProx® II Card – up to 5″ (12.7 cm)
DuoProx® II Card – up to 5″ (12.7 cm)
Smart ISO/DuoProx™ Cards – up to 5″ (12.7 cm)
Proximity & MIFARE™ Card – up to 5″ (12.7 cm)
ProxCard® Plus Card – up to 1.5″ (3.8 cm)
ProxKey® II Keyfob – up to 2″ (5.1 cm)
Microprox® Tag – up to 3″ (7.6 cm)
*Depending on local installation conditions.
Dimensions
4.70″ x 3.00″ x 0.68″ (11.9 x 7.6 x 1.7 cm)
Power Supply
5-16 VDC
Linear power supplies are recommended.
Current Requirements
Average: 30 mA (5 VDC); 20 mA (12 VDC)
Peak: 110 mA (5 VDC); 115 mA (12 VDC)
Operating Temperature
-22º to 150º F (-30º to 65º C)
Operating Humidity
0-95% relative humidity non-condensing
Weight
3.3 oz. (94 gm)
Cable Distance
Wiegand interface: 500 feet (150 m)
Clock-and-data interface: 50 feet (15 m)
Recommended cable is ALPHA 1295 (22 AWG) 5 conductor minimum stranded with overall shield or equivalent. Additional conductors may be required for LED or beeper control.
Certifications
Canada/UL 294 Listed
FCC Certification, United States
Canada Certification
EU and CB Scheme Electrical Safety (EN60950 and IEC60950 ITE Electrical Safety)
Fifteen EU Countries under the R&TTE Directive (EN300 330 – SRD, and ETS 300 683 – EMC)
CE Mark
Australia C-Tick, New Zealand
Taiwan, China